31 - Condensation
Completion requirements
10. Condensation Inside Horizontal Tube
\[\boxed{h_m = 0.555\left[\frac{g\rho(\rho-\rho_v)\lambda k^3}{\mu (T_v-T_w)D}\right]^{1/4} }\] where \(D\) is the inside diameter of tube.